Author Topic: New HP Prime OS Version: 2014.0331  (Read 22060 times)

0 Members and 1 Guest are viewing this topic.

Offline timwessman

  • LV3 Member (Next: 100)
  • ***
  • Posts: 94
  • Rating: +32/-0
    • View Profile
New HP Prime OS Version: 2014.0331
« on: May 27, 2014, 12:44:47 pm »
For your emulator, calculator and connkit. Easiest way to get them is to use the check for update mechanism in the emulator or connkit.

The primary focus of this release in terms of new features was improvement of geometry and statistics. The primary focus of the connkit was around the main UI (not the editors for specific object types which were essentially untouched).

Four chapters in the user guide were changed, however they could not be rolled directly into the original document and are instead a "supplement" for now. The emulator has them, but they are attached to the end of the existing manual brought up by selecting Help->User Guide in the emulator windows menu. If you'd like the separate "supplement" file, it should be up on the HP support page shortly.

Spoiler For Release Notes:
Quote
HP Prime – Release Notes
-------------------------

Date Released: 2014/03/31

Internal Versions
-----------------
          Firmware Version:     2014 03 31 (6030)
Virtual Calculator Version:     2014 03 31 (6031)
          Connectivity Kit:     2014 03 31 (6026)

Description
-----------
This release of the Prime Calculator firmware and associated PC software delivers significant new features and fixes outstanding issues. This document is not a complete list of all changes, but highlights specific items. All users of the HP Prime calculator are encouraged to upgrade for the best possible experience.

Backward Compatibility
----------------------
There is limited backward compatibility between this and earlier releases.

Older Prime hardware (Revision A) does support this release, however the wireless, unit-to-unit, and data streamer functionality is not supported on earlier models. In the Help->About HP Prime screen the hardware revision will be displayed along with software version information. Mixing and matching software revisions is not encouraged and may cause unexpected results. Users are strongly encouraged to first backup their calculators with the older firmware and Connectivity Kit - then upgrade all their calculator software (firmware, Connectivity Kit, and Virtual Calculator).  Upgrade the Connectivity kit first, before upgrading your calculator firmware. This order will produce the best experience.

The geometry application and inference have received significant updates and earlier data files will not be compatible. Old data files from earlier revisions will not load and and a new empty data file will overwrite the old one.

Due to some specific issues resolved, certain user programs may not run on the new system without changes first. Specifically, any commands with the Σ character in the name may need to be corrected to use the correct sigma character. Function variables will now also error if the function parameter is using a reserved system function name (example: SIN or COLOR). Additionally, the TRIANGLE commands were modified to allow TRIANGLE, LINE and FILLPOLY to share similar data and syntax to enable easier creation of complex 3D drawings

New Functionality (Connectivity Kit)
------------------------------------
1.    Application has had major improvements to the user interface. Please refer to the included connectivity kit User's Guide for instructions and details.
2.    Support for the HP Wireless Classroom network has been introduced. Please see http://www.hp.com/calculators/ for details on the Wireless Classroom kit.
3.    Greatly enhanced communication speed over USB link to calculator.

New Functionality (Calculator Software)
---------------------------------------
1.    Improved touch support throughout system. This includes pinch to zoom support in graphing applications, and kinetic scrolling.
2.    Pressing HELP in an open command line will attempt to find the name of a command based on the prior input up to the cursor position to display system help for that command.
3.    Includes Edition 2 of the on calculator help files (English only in this release).
4.    Greatly enhanced robustness and capability of the Statistics 2Var logistic fit.
5.    Wireless support for capable units turned on. Wireless icon will appear in the right top corner menu for units that can support the HP Prime Wireless Kit.
6.    Calculator unit-to-unit communications has now been enabled on units that can support it.
7.    Numerical values now can be displayed with digit groupings. Examples include: 1,234.567               1 234.567 and 1’234,567
8.    Two new numerical display formats have been introduced. These are “floating” which only displays up to a specified number of digits, and “rounded” which is similar to the “fixed” format except trailing zeros are suppressed.
9.    Decimal fractions now appear with a zero, as in 0.25.
10.    Vectors are now displayed as a single line object until they become a matrix. This aids in distinguishing vectors and matrices.
11.    User selectable first day of week setting for use through the system.
12.    First boot unlock and settings wizard. User will be asked to confirm language selection and some initial settings.
13.    Inference application now can do Chi-Square calculations and Linear Regression T calculations.
14.    Geometry application has been completely redone and is much faster, consistent, and capable than before.
15.    Enhanced color pickers allow a greater range of color selection.
16.    Pressing ENTER will now open chooser in a dialog or toggle checkbox.
17.    Enhanced unit object display to ensure a more standard form with complex units.
18.    TRIANGLE, FILLPOLY and LINE commands can now draw multiple objects in a consistent way with each other. Useful for very complicated 3D drawing in user programs.
19.    INPUT command can now create multi-page dialogs and contain choose boxes, check boxes and grouped check boxes. It can also allow specific item types and gives control of parsing behavior for input. It also supports size and position control.

New Functionality (Virtual Calculator)
--------------------------------------
1.    A horizontal skin has been included for use with monitors that are restricted in the vertical pixel range.

Resolved issues and changes excluding CAS
-----------------------------------------
1.    Resolved issue with statistics 2 variable trig fit causing poor curve fit.
2.    Resolved issue with removing last row or column from a CAS matrix in the matrix editor.
3.    Resolved issue with .^ and ./ function calculations.
4.    Resolved issue with EDITLIST/EDITMAT commands not working in RPN mode.
5.    Resolved issue with BLIT command when specified destination was a zero sized region.
6.    Resolved several issues with fraction key in home to make behavior more consistent.
7.    Resolved issue in 2D integral template where EEX key would always add a 1 before the E in the evaluation limit locations.
8.    Resolved several issues where integer only settings fields would display using the current display setting.
9.    Resolved issue where auto power off did not function in graphing applications.
10.    Resolved issue with commands EDITLIST and EDITMAT using user defined variables.
11.    Resolved issue with key buffer not being cleared when the user aborts a running program.
12.    Resolved issue with auto off timer in plot gallery not being reset on user touch.
13.    Resolved issue with auto-off timer in plot gallery not being reset on user input.
14.    Resolved issue with copy and paste in spreadsheet.
15.    Resolved issue with sigma character in command names not being consistent through entire system.
16.    Resolved issue with RETURN call inside repeating loop in a user program.
17.    Resolved issue with object printing in debugging interface causing unpredictable behavior.
18.    Resolved problem with integration calling ABS(F1(X))
19.    Resolved issue with G0-G9 in user programs while spreadsheet was active application.
20.    Resolved issue with 10 second periodic wakeup during sleep reducing long term shelf life.
21.    Resolved issue with KWh in menu needing to be named kWh to function properly.
22.    Resolved issue where storing a number to a vector padded with too many zeros.
23.    Resolved issue with clicking EDIT menu after deleting last CAS object from memory manager catalog.
24.    Resolved issue with negative and STO conversion shortcut.
25.    Resolved issue where tapping an item in Advanced Grapher Symbolic view behaved differently then tapping edit menu key.
26.    Resolved issue where calculating integration with boundary at 0 appeared to fail.
27.    Resolved issue with case sensitivity in note and program catalog.
28.    Resolved issue where changing font size could cause strange artifacts in 2d equation display in Symbolic view.
29.    Resolved problem where copying .+ or .- operators would not insert space before commands.
30.    Resolved issue with ΣLIST and a vector argument.
31.    Resolved some issues with F1 and CAS interaction.
32.    Resolved issue with the UNITS -> TOOLS menu commands not evaluating immediately in RPN mode.
33.    Resolved issue with eigenvectors of diagonal matrices in home.
34.    Resolved issue where DMS toggle on home screen did not work with certain numbers.
35.    Resolved issue with RPN stack not being cleared by a clear in memory manager.
36.    Resolved issue where changing HEX or other similar settings did not update stack display immediately.
37.    Resolved issue where clearing memory from catalog did not clear Ans variables.
38.    Resolved issue where pressing BKSP on a CAS variable from chooser did not delete it.
39.    Resolved issue where CAS screen would have left/right alignments disrupted after a power cycle.
40.    Resolved issue with logb and very tiny values.


Resolved issues and changes in CAS
----------------------------------
1.    Resolved issue with for desolve([y'=sqrt(y),y(1)=1],x,y)
2.    Resolved issue  with units in approx mode and auto simplification on units
3.    Added check for real matrix in SVD
4.    Resolved issue with tlin(cos(a)*cos(b)) and with plot(exp(-x^2))
5.    Resolved issue with odesolve in reverse time direction
6.    Desolve now handles linear system with constant coefficients; for example, desolve([y'=[[1,2],[2,1]]*y+[x,x+1],y(0)=[1,2]]);
7.    Resolved issue with int(surd(2x,3),x,0,4), and with simplify(sin^2+cos^2)
8.    Improved display for some sqrt results like sqrt(2+sqrt(3)) as sqrt(2)/2+sqrt(6)/2
9.    Resolved issue with speed of int(x*exp(-x^2),x,0,100)
10.    Resolved issue with derivative of composition e.g. (g(x^2))'
11.    Resolved issue with desolve([y''-2*y'/x+(9+2/x^2)*y=x*exp(x),y(pi/6)=0,y(pi/3)=0],y)
12.    Make SVD (SVL) work on rectangular matrices.
13.    Change interpretation of A/B where B is a square matrix to inv(B)*A with a warning
14.    Resolved issue with integer factorization.
15.    Make limit(1/x^2,x,0) return +infinity instead of unsigned infinity
16.    Resolved issue with laplace(exp(a*x),x,t)
17.    Resolved issue with ilaplace(exp(-3x))
18.    Resolved issue with sigma notation
19.    Resolved issue with sign (-> also fixes laplace(x))
20.    Make ifactor return an error if number too large
21.    Resolved issue with recursion issue in geometry objects evaluation
22.    Resolved issue with inv((5.+8i)^200)
23.    Resolved issue with tan(54) in degree mode
24.    Resolved issue with matrix/vector * object, if one arg to * is approx, evalf the other one with current context modes (instead of null context).
25.    Extend cholesky to hermitian complex matrices
26.    Resolved issue with ifactor(nextprime(alog10(17))*nextprime(alog10(19)));
27.    Resolved issue with collect(sqrt(4x^2)) and for solve(-x+1=surd(-x^3+7,3));
28.    Resolved issue with int(int(sqrt(x+y),x,0,1),y,0,1)
29.    pa2b2(2) now returns [1,1]
30.    legendre_symbol and jacobi_symbol now accept negative first argument
31.    Resolved issue with algebraic extension with i inside
32.    op added to list of non auto simplified operators + dichotomic search
33.    Default interval changed for parabola
34.    Make left and right accept an integer represented as a double as 2nd argument
35.    Set max list size to 10 000 and compute factorial exactly up to 1000 on hardware
36.    Resolved issue with hadamard on numeric matrices
37.    Size limit check added for $, Ans support for SCALE/SCALEADD/...
38.    Resolved issue with re/im/abs e.g. im(sqrt(x)+1)
39.    Size check added for JordanBlock, fix for solve with fractional powers,
40.    Resolved issue with iPart with neg argument
41.    element added to the list of functions that should not be auto simplified
42.    RANDMAT with one argument accepted.
43.    Changes for triple matrix norm (l1norm, l2norm, linfnorm)
44.    Resolved issue with resultant with num coeffs
45.    mat2list sets HP list subtype for the result.
46.    Resolved issue with plotfunc(normald(x))
47.    area now accepts a function plot as first argument, 2nd argument a..b, or 2nd argument a, 3rd argument b, returns area under curve. For a parametric plot, a and b are the parameter range.
48.    ifactor check added for qsieve failure
49.    Resolved issue with ARG in degree
50.    Resolved issue with fPart/iPart for negative/complex arguments
51.    Resolved issue with asin(sin(pi))) and acos(cos(pi)) in degree
52.    Change for [] in CAS: start at 1
53.    Resolved issue with definite integral with inf boundary in degree mode
54.    Replace warning by error for recursive definition except for when/ifte/program
55.    Improve non-directional limit, e.g. limit(1/abs(x),x,0)
56.    Enable for and if as lowercase synonyms for FOR and IF in the CAS.
57.    Make REDIM and REPLACE (CAS version) accept a matrix instead of a variable name as 1st arg.
58.    Resolved issue with regroup(inf) and for FP
59.    Resolved issue with poisson_cdf with 3 arguments
60.    Resolved issue with circle tangent, using relative error instead of absolute error.
61.    Handling of inequalities with approximate coefficients using an exact conversion
62.    jordan for numeric matrix with exact coefficients but no exact eigenvalue converting to approx.
63.    Resolved issue with assume(s<0); sign(s)
64.    Tangent for conics now use rational parametric equation
65.    Resolved issue with a%%b if b is not an integer
66.    Resolved issue with locus, fix for table print/parse
67.    Resolved issue with l2norm
68.    Re-set angle mode in isopolygon.
69.    Leave propfrac unsimplified
70.    Make sum eval approx if exact mode is not checked
71.    Boolean operators now return 1/0
72.    Resolved issue with col, suppress and makemat (indices starting at 1)
73.    Better handling for some 4th order equations.
74.    Set complex_variables to false in arcLen so that arcLen(x^2,x,0,1) works if Complex is checked.
75.    Additional check for duplicate argument name in CAS program exit.

Important Note: If you updated your hardware unit before Thurs, May 29, GMT-6 please redownload and update your Prime firmware.

1. Delete the "My Documents\HP Connectivity Kit\Temp" directory, and "HP Connectivity Kit\Firmware" directory.
 2. Run the check for update again. It will re-download the firmware zip file from today.
 3. Reinstall on your unit using the new files.
« Last Edit: May 29, 2014, 03:34:40 pm by timwessman »
TW

Although I work for the HP calculator group, the comments and opinions I post here are my own.

Offline Streetwalrus

  • LV12 Extreme Poster (Next: 5000)
  • ************
  • Posts: 3821
  • Rating: +80/-8
    • View Profile
Re: New Version: 2014.0331
« Reply #1 on: May 27, 2014, 12:59:56 pm »
That's quite a long list of fixes. O.O Nice to see you are working on resolving these. :)

Offline timwessman

  • LV3 Member (Next: 100)
  • ***
  • Posts: 94
  • Rating: +32/-0
    • View Profile
Re: New Version: 2014.0331
« Reply #2 on: May 27, 2014, 01:10:59 pm »
Its better to give the information out rather then hide it IMO...
TW

Although I work for the HP calculator group, the comments and opinions I post here are my own.

Offline Streetwalrus

  • LV12 Extreme Poster (Next: 5000)
  • ************
  • Posts: 3821
  • Rating: +80/-8
    • View Profile
Re: New Version: 2014.0331
« Reply #3 on: May 27, 2014, 01:14:04 pm »
Of course it is. Unlike TI who doesn't give a **** about users anymore, you guys are doing serious work.

Offline Eiyeron

  • Urist McEiyolobster
  • LV10 31337 u53r (Next: 2000)
  • **********
  • Posts: 1430
  • Rating: +130/-10
  • (-_(//));
    • View Profile
    • Rétro-Actif : Rétro/Prog/Blog
Re: New Version: 2014.0331
« Reply #4 on: May 27, 2014, 01:19:19 pm »
I don't have a HP Prime but I'm happy to see that you're actively working on your products. Could you add some details on what features are planned?

Offline Hayleia

  • Programming Absol
  • Coder Of Tomorrow
  • LV12 Extreme Poster (Next: 5000)
  • ************
  • Posts: 3367
  • Rating: +393/-7
    • View Profile
Re: New Version: 2014.0331
« Reply #5 on: May 27, 2014, 01:25:20 pm »
Wow, it's great to see you are working on it :D
And it's a good idea to provide a detailed changelog (as opposed to this changelog for example) so that people who reported bugs can see that you fixed them :)
I own: 83+ ; 84+SE ; 76.fr ; CX CAS ; Prizm ; 84+CSE
Sorry if I answer with something that seems unrelated, English is not my primary language and I might not have understood well. Sorry if I make English mistakes too.

click here to know where you got your last +1s

Offline Streetwalrus

  • LV12 Extreme Poster (Next: 5000)
  • ************
  • Posts: 3821
  • Rating: +80/-8
    • View Profile
Re: New Version: 2014.0331
« Reply #6 on: May 27, 2014, 01:29:01 pm »
Hayleia, do you mean this ?
* Streetwalrus runs

Offline timwessman

  • LV3 Member (Next: 100)
  • ***
  • Posts: 94
  • Rating: +32/-0
    • View Profile
Re: New Version: 2014.0331
« Reply #7 on: May 27, 2014, 01:30:42 pm »
Quote
Could you add some details on what features are planned?

Unfortunately, no.

HP does not allow any future information of any kind to be given. Any questions around "what is coming", "what has been fixed", "when", etc are forward looking statements and are not allowed. It is extreemly common for companies to work that way. In fact, many companies don't allow *any* communication of any kind except by an autorized communication person and hence it is just a bag of silence.

Excluding all possible legal issues, how would you feel if someone said "<insert thing here> is going to be fixed in the next release" or "We are adding <feature Y>" and then it didn't come out like was stated? Perhaps the issue ended up being more complicated then expected or in testing it was determined the fix wasn't complete. Maybe the people who needed to work on it had to work on something else. Maybe it was decided to roll it into another release with similar things. Etc.

I know that would tick me off personally.  :)
TW

Although I work for the HP calculator group, the comments and opinions I post here are my own.

Offline Hayleia

  • Programming Absol
  • Coder Of Tomorrow
  • LV12 Extreme Poster (Next: 5000)
  • ************
  • Posts: 3367
  • Rating: +393/-7
    • View Profile
Re: New Version: 2014.0331
« Reply #8 on: May 27, 2014, 01:37:17 pm »
Hayleia, do you mean this ?
* Streetwalrus runs
Well the one I linked to is worse. At least in yours you know that nothing changed, but in mine you don't even know, it might be the case or not. And most of all, yours is a joke while mine is true o.o
I own: 83+ ; 84+SE ; 76.fr ; CX CAS ; Prizm ; 84+CSE
Sorry if I answer with something that seems unrelated, English is not my primary language and I might not have understood well. Sorry if I make English mistakes too.

click here to know where you got your last +1s

Offline Streetwalrus

  • LV12 Extreme Poster (Next: 5000)
  • ************
  • Posts: 3821
  • Rating: +80/-8
    • View Profile
Re: New Version: 2014.0331
« Reply #9 on: May 27, 2014, 02:43:24 pm »
Hayleia, do you mean this ?
* Streetwalrus runs
Well the one I linked to is worse. At least in yours you know that nothing changed, but in mine you don't even know, it might be the case or not. And most of all, yours is a joke while mine is true o.o
But TI actually released it. :P That's right. Changelog : nothing.

Also Tim, I totally understand that. This is serious business, you don't mess with teasers to let people down afterwards.

Offline DJ Omnimaga

  • Clacualters are teh gr33t
  • CoT Emeritus
  • LV15 Omnimagician (Next: --)
  • *
  • Posts: 55943
  • Rating: +3154/-232
  • CodeWalrus founder & retired Omnimaga founder
    • View Profile
    • Dream of Omnimaga Music
Re: New Version: 2014.0331
« Reply #10 on: May 27, 2014, 03:47:38 pm »
Awesome news! Also, an admin should move this to the news sub-forum (while making sure to leave a redirect link in this sub-board) since I can no longer do it myself.

I am updating the emulator and connectivity kit right now, but when I tried to update the emulator the updater froze D: (EDIT: Nvm, manual reinstall did it and my calc updated fine on 2nd try. WARNING: When the Autoplay box appears in WIndows, do not close it, else this will stop the firmware update and fail.)
« Last Edit: May 27, 2014, 04:01:29 pm by DJ Omnimaga »

Offline Juju

  • Incredibly sexy mare
  • Coder Of Tomorrow
  • LV13 Extreme Addict (Next: 9001)
  • *************
  • Posts: 5730
  • Rating: +500/-19
  • Weird programmer
    • View Profile
    • juju2143's shed
Re: New Version: 2014.0331
« Reply #11 on: May 27, 2014, 04:06:00 pm »
I'll edit it a little so it makes a proper news and I'm moving it, if you don't mind.

Remember the day the walrus started to fly...

I finally cleared my sig after 4 years you're happy now?
THEGAME
This signature is ridiculously large you've been warned.

The cute mare that used to be in my avatar is Yuki Kagayaki, you can follow her on Facebook and Tumblr.

Offline DJ Omnimaga

  • Clacualters are teh gr33t
  • CoT Emeritus
  • LV15 Omnimagician (Next: --)
  • *
  • Posts: 55943
  • Rating: +3154/-232
  • CodeWalrus founder & retired Omnimaga founder
    • View Profile
    • Dream of Omnimaga Music
Re: New HP Prime OS Version: 2014.0331
« Reply #12 on: May 27, 2014, 05:13:17 pm »
On a side note, is the missing Send button in the emulator because all transfer abilities were moved to the connectivity kit or is this just a bug?

Offline Hexatron

  • LV3 Member (Next: 100)
  • ***
  • Posts: 76
  • Rating: +2/-1
    • View Profile
Re: New HP Prime OS Version: 2014.0331
« Reply #13 on: May 27, 2014, 05:36:19 pm »
>This includes pinch to zoom support in graphing applications
inb4 Apple sues HP for pinch-to-zoom functionality

Offline Streetwalrus

  • LV12 Extreme Poster (Next: 5000)
  • ************
  • Posts: 3821
  • Rating: +80/-8
    • View Profile
Re: New HP Prime OS Version: 2014.0331
« Reply #14 on: May 27, 2014, 05:40:17 pm »
>This includes pinch to zoom support in graphing applications
inb4 Apple sues HP for pinch-to-zoom functionality
^ That. Also, the glass and aluminium design.
* Streetwalrus runs